ETDRS Acuity

ETDRS acuity testing has become the worldwide standard for visual acuity testing, replacing the Snellen and Sloan acuity tests. ETDRS stands for Early Treatment Diabetic Retinopathy Study. The ETDRS test is designed to eliminate inaccuracies in the Snellen and Sloan tests.

 

Standardized ETDRS – CSV-2000, CSV-1000 and ESV-3000

Standardized ETDRS – CSV-1000 and ESV-3000
CSV-1000 ETDRS

The CSV-2000, CSV-1000 and ESV-3000 ETDRS offer automated, self-calibrating standardized test lighting for ETDRS, to ensure consistent and accurate results. The CSV-2000 is a fully computerized testing system which displays the ETRDS test charts on a computer monitor. The computer display light level is standardized through a patented technology called “AcQviz.” The CSV-1000 offers a backlit ETDRS test and incorporates highly advanced miniature fluorescent light source technology that is standardized through automated calibration circuitry. The ESV-3000 is a large-format backlit ETDRS test device that incorporates advanced LED light source technology, also standardized through automated calibration circuitry. In each device, the auto-calibration circuitry constantly monitors the testing light source and calibrates each to a test luminance of 85 cd/m2.  The ESV-3000 can also be set to calibrate to a light level of 3 cd/m2. Other ETDRS testers are not standardized as they have no circuitry to control the test lighting. They employ non-standardized computer monitors or “off-the-shelf” fluorescent bulbs that require a bulb “burn-in” period. For these other units, the light levels often drift or change in brightness over time and for their bulbs, as they age. they must be constantly replaced. Each time a bulb is replaced, there is an additional “burn-in” period. No testing can be accomplished during the “burn-in” period.

 

CSV-2000

The CSV-2000 allows testing up to 20/200 in the ETDRS testing format at a test distance of 10 feet. The device is computerized and operated by hand held remote control.
 

CSV-1000 ETDRS

The CSV-1000 allows testing up to 20/200 at a test distance of 8 feet, or up to 20/125 at a distance of 4 meters. The device is operated by infrared remote control.

 

ESV-3000 ETDRS

ESV-3000 ETDRS
ESV-3000 ETDRS

The ESV-3000 is the only large-format standardized ETDRS testing device. The ESV-3000 allows testing up to 20/200 ETDRS Acuity at a test distance of 4 meters The device is operated by infrared remote control. The ESV-3000 is designed specifically for clinical trials where large-format ETDRS testing (up to 20/200) is performed at 4 meters. Unlike other large-format back-lit devices for ETDRS evaluation, the light level is calibrated and held constant, allowing the automatic replication of testing light levels from different clinical trials locations or for evaluating before and after treatment.

A wide variety of ETDRS LogMAR tests are available for both the CSV-1000 and the ESV-3000, including Chart R, Chart 1, Chart 2, Tumbling E, Lea Symbols and many others.

 

ETDRS Background

The ETDRS acuity test was developed to aid in evaluating the changes in vision following panretinal photocoagulation in patients with diabetic retinopathy. Previous studies had somewhat confusing results due to inadequacies of the acuity tests used in those early studies. For example, the Snellen acuity test has a different number of letters per row, e.g. 10 letters on the 20/20 line, but only 3 letters on the 20/70 line. Therefore, if the results of a study showed that the patients “gained three letters of acuity,” the results could indicate the gain of a full acuity line, as in the 20/70 line, or only a portion of an acuity line, as in the 20/20 line. Also, the individual lines on the Snellen acuity test are not equally spaced. For example, the change from the 20/25 line to the 20/20 line is a 20% change, while the change from the 20/30 line to the 20/25 line is a 16% change. Again, referring back to the diabetic studies, if a study demonstrated a two line increase in acuity, it could mean a 33% improvement from 20/30 to 20/20, or a 40% improvement from 20/50 to 20/30. These inadequacies of the Snellen acuity test made it impossible to properly evaluate the acuity data and to compare data from study to study.

Other inadequacies also exist in the Snellen Acuity test. These include the types of letters used on the test and the spacing of the letters. These details are beyond the scope of this website, but if there are questions involving the more detailed design characteristics of the ETDRS chart, please feel free to call us at 800 526 7703 or 937 548 7970.

 

ETDRS Design

The ETDRS test incorporates specific design criteria to make it more accurate than the Snellen or Sloan acuity tests. These include:

  • Same number of letters per row (five letters per row)
  • Equal spacing of the rows on a log scale (the rows are separated by 0.1. log unit)
  • Equal spacing of the letters on a log scale
  • Individual rows balanced for letter difficulty

To prevent memorization, different versions of the ETDRS test chart are available. The three standard versions of the ETDRS chart are R, 1 and 2.

 

ETDRS Standardization

To properly evaluate ETDRS, the test should be conducted under standardized lighting conditions. The CSV-1000 and ESV-3000 are the only devices that self-standardizes the test lighting level to the recommended photopic test level of 85 cd/m2. This light level has been recommended by the National Academy of Sciences and by the American National Standards Institute for ETDRS and contrast sensitivity vision testing.

 

Scoring the ETDRS Chart

ETDRS scoring can be accomplished in a number of different ways. The two most common methods are described below. Both of these methods provide scores that can be used for statistical analysis, unlike the scores provided by the standard Snellen or Sloan Acuity tests.

 

ETDRS Scoring Method 1

The patient starts are the top of the chart and begins to read down the chart. The patient reads down the chart until he or she reaches a row where a minimum of three letters on a line cannot be read. The patient is scored by how many letters could be correctly identified.

 

ETDRS Scoring Method 2

The ETDRS charts were originally used in ETDRS studies where patients had relatively poor vision. For these studies, starting patients at the top of the chart to read down worked well since most patients could read only about half way down the chart. However, the ETDRS charts are now being widely used for many studies, including IOL and refractive surgery studies, where patients have very good vision. For these patients, it makes little sense to start them at the top of the chart and read down. For these patients, a second scoring method is used. The patient starts on the last row where he or she can read all of the letters, and then reads down until he or she reaches a row where a minimum of three lines cannot be read. For these patients, a decimal ETDRS acuity score can be used. To calculate the decimal acuity score, follow the guidelines below. (In reality, scoring method 1 can also be used for statistical analysis, by assuming that the patient could have read all of the letters above where he or she started on the test. Then add that number of letters on to the number of letters actually read by the patient.)

  • Determine the last row where the patient can correctly identify all 5 letters on that row.
  • Determine the log score for that row (these scores are shown in the margin of the ETDRS test, e.g. the 20/25 line has a log score of 0.1)
  • subtract 0.02 log units for every letter that is correctly identified beyond the last row where all of the letters are correctly identified. For example, if the patient reads all of the letters correctly on the 20/32 row and then 3 letters correctly on the 20/25 row, the Log Score would be calculated as follows:

20/32 Row = 0.20
3 letters X 0.02 log/letter = – 0.06
ETDRS Acuity Log Score = 0.14

 

How Are Bailey-Lovie Charts and ETDRS different?

Bailey-Lovie charts incorporate the European design of LogMAR, where letter sizes are rectangular instead of square. For example, a 20/20 ETDRS letter is square, 5 minutes of arc by 5 minutes of arc. For the Bailey-Lovie Chart Design, a 20/20 letter is 4 minutes of arc by 5 minutes of arc.

Featured Product

CSV-2000

CSV-2000 The first and only all-in-one digital vision testing device that offers the full range of vision tests, along with STANDARDIZED contrast sensitivity, glare and visual acuity.

feature-slide01

AcQviz Auto-Calibration

Includes the patented AcQviz technology that automatically measures monitor luminance and adjusts testing to the recognized FDA vision testing luminance standard of 85 cd/m2.


  • Standardized to the testing light level recommended by the FDA and ANSI

  • Easy-to-use remote control allows rapid integration into patient flow

feature-slide02

Full Range of Vision Tests

Includes the full range of vision tests, including acuity, astigmatism, convergence, color, depth, etc. and the proprietary VectorVision contrast sensitivity and glare tests.


  • Standardized to the testing light level recommended by the FDA and ANSI

  • Easy-to-use remote control allows rapid integration into patient flow

feature-slide03

Scientifically Validated Contrast Sensitivity Testing

Uses the same contrast and spatial frequency range that is validated by more than 100 scientific papers and provides the only published population age-norms.


  • Standardized to the testing light level recommended by the FDA and ANSI

  • Easy-to-use remote control allows rapid integration into patient flow

feature-slide01

Rapid Testing

Remote control provides the ability to easily switch between tests. All tests are designed specifically for a computerized format, thus making testing fast and easy.


  • Standardized to the testing light level recommended by the FDA and ANSI

  • Easy-to-use remote control allows rapid integration into patient flow

Why VectorVision?®


As treatments evolve, so must the testing technology

View More Videos

Over the last 20 years, VectorVision testing equipment has become the worldwide benchmark for standardized contrast sensitivity, glare and ETDRS acuity testing.

Read our Reviews